SPECIFICATION

Parameter Unit Value
Capacity (Emax) t 20; 30; 40; 60; 100
Accuracy class according to GOST30129 (OIML R60) С1 С3
Number of verification intervals 1000 3000
Minimum verification interval Emax/5000 Emax/10000
Rated output (RO) mV / V 2 ± 0.010 2 ± 0.002
Dead load output % RO < 3 < 3
Combined error % RO ±0.030 ±0.020
Creep error (30 min.) % RO ±0.049 ±0.025
Temperature effect on minimum dead load output % RO / °C ±0.0028 ±0.0014
Temperature effect on rated output % RO / °C ±0.0022 ±0.0011
Maximum excitation voltage V 12
Input resistance 1150 ± 50
Output resistance 1000 ±2
Insulation resistance M ≥ 5
Compensated temperature range °C -10...+40
Operating temperature range °C -50...+50
Storing temperature range °C -50...+60
Protection class according to GOST 14254 IP68
Safe overload (1 hour) % Emax 25
Ultimate load % Emax 300
Load cell material Stainless steel


DIMENSIONS

Value, t H1, mm H2, mm H3, mm H4, mm H5, mm H6, mm H7, mm H8, mm D1, mm D2, mm R, mm αmax Smax, mm Fr, % Value Mass loadcell, кг Length of a cable, m
20 150 75 35,5 35 18 10 44,5 68 44 75 160 10,5 7,9 3,7 16
30 150 75 35,5 35 18 10 44,5 68 44 75 160 10,5 7,9 3,7 16
40 150 75 35,5 35 18 10 44,5 68 44 75 180 10,5 9,7 3,7 16
60 150 75 35,5 35 18 10 44,5 68 44 75 200 10,5 11,6 3,7 16
100 178 89 35,5 34 17 10 62,2 81 62 101 290 11,4 14,3 5,9 16